ProKure V Dilution Rate: 100 ppm ClO2 Activation Guide
ProKure V reaches 100 ppm chlorine dioxide when you match one packet to its water volume: the 0.042 oz (1.19 g) packet in 1 quart (32 oz), the 0.17 oz (5 g) packet in 1 gallon, the 0.84 oz (23.8 g) packet in 5 gallons, and the 3.36 oz (95.2 g) packet in 20 gallons. Drop the sealed white inner pouch into an opaque container, agitate for one minute at 15-minute intervals, and allow one hour to reach full strength. To disinfect hard, non-porous surfaces, hold them visibly wet for 10 minutes at 100 ppm. No rinse. That is the whole answer; the rest is why and how.
The 100 ppm dilution table (print this and hang it in the mix room)
The pairing is one packet to one water volume. You do not do partial packets or custom math. Each packet is sized to hit a nominal 100 ppm at exactly one volume.
| Packet size | Water volume | Result | --- | --- | --- | 0.042 oz (1.19 g) | 1 quart (946 mL) | 100 ppm ClO2 | 0.17 oz (5 g) | 1 gallon (3.7 L) | 100 ppm ClO2 | 0.84 oz (23.8 g) | 5 gallons (18.9 L) | 100 ppm ClO2 | 3.36 oz (95.2 g) | 20 gallons (75.7 L) | 100 ppm ClO2 |
Those figures are the ProKure V directions-for-use label values, verbatim. A reseller product listing corroborates the same pairing, stating a 0.84 oz packet with 5 gallons of water produces a 100 ppm chlorine dioxide solution. If you need a lower working concentration, the label gives two dilutions from the 100 ppm stock: 1 part stock to 4 parts water yields 20 ppm, and 1 part stock to 19 parts water yields 5 ppm. For routine surface disinfection in a cultivation room, 100 ppm is the number you want.
This single, complete table is the reason this page exists. The #1 search result for this exact query is a brand FAQ that answers PPE and residue questions but never prints a packet-to-water chart, so the reader who came for a number bounces. We lead with the number.
What 100 ppm actually means, and why the SDS says 500
Parts per million is just a ratio: 100 ppm is 100 milligrams of chlorine dioxide per liter of solution, which is why the packet is pre-weighed to the water volume. You are not mixing a percentage, you are dropping a measured dose into a measured volume. For a QA lead documenting an audit trail, that is the useful framing: the concentration is fixed by the packet and the water, not by a field measurement.
Two numbers trip people up. A ProKure V safety data sheet notes the product is designed to generate up to a 500 ppm chlorine dioxide solution, while the use directions say 100 ppm. Both are correct. The 500 ppm figure is the product's design ceiling, the maximum the chemistry can produce, while 100 ppm is the EPA label use-direction concentration for disinfecting hard, non-porous surfaces. You dose to the label number, 100 ppm, not to the ceiling. Using an EPA-registered product in a manner inconsistent with its labeling is a violation of federal law, so the label number governs.
ProKure V is water-activated ClO2 technology, EPA Reg. No. 87508-3-89334, and at 10 minutes at 100 ppm it is an effective fungicide against the organisms named on its label, including Aspergillus niger. For the full chemistry primer, seeair quality management.
Step-by-step activation at 100 ppm
The procedure is short, and the order matters.
First, choose the packet that matches your water volume from the table above. Second, use an opaque (not clear) container; light degrades the activating solution. Third, tear open the foil package, remove the white inner pouch, and drop it in whole. Do not open or tear the white inner pouch; that is the most common user error. Fourth, agitate for one minute, repeat at 15-minute intervals, five agitations total, and let it reach full strength at one hour, keeping the temperature between 20 and 25 degrees Celsius. Fifth, apply by sprayer, mop, or sponge; do not fog it. Sixth, keep treated surfaces visibly wet for the full 10-minute contact time. Seventh, no rinse is required and it leaves no residue, so let surfaces air-dry.
If your solution looks pale or weak after an hour, check two things: did you use a clear container, and did you hold 20 to 25 degrees Celsius. Both affect activation. Run the between-cycle surface reset as a documentedmold prevention protocol.
Contact time: why the 10-minute hold is not optional
The dilution gets you to 100 ppm. The contact time is what actually disinfects. The label requires an exposure time of 10 minutes at 100 ppm to disinfect hard, non-porous surfaces, which means the surface must stay visibly wet with activated solution for the full ten minutes. Wipe it dry at eight minutes and you have not met the label condition, so you cannot claim disinfection; you have cleaned, not disinfected.
This is the part every ranking page buries in a single sentence. For a facility manager running a between-harvest reset, treat the ten minutes as a timed step: spray to visible wetness, start a timer, re-wet any surface that flashes dry in dry-room air, and only then move on. The one exception on the label is SARS-CoV-2, which is a 30-second claim at 100 ppm; every other organism on the list runs on the 10-minute hold.
PPE, plants in the room, and the surfaces this is approved for
Here is the question growers actually post to community threads, answered plainly. At 100 ppm, ProKure V does not require respiratory PPE. Gloves are required only if your hands will contact the activated solution during dilution or application. That is the whole PPE story at this concentration; for the fuller breakdown see the product label on prokuresolutions.com.
Two label facts look contradictory until you see the distinction. ProKure V is approved to use on hard, non-porous surfaces, not directly on plants, and it is also suitable for use with plants in the room. Both are true: you apply it to surfaces (grow beds, trays, drying-room walls, drop-down hoses, stainless steel, glass, vinyl, PVC, polypropylene), not onto foliage, and the plants can stay in the space during that surface treatment. The restriction is about where the spray lands, not whether the room is occupied. Because it leaves no residue and carries an NSF International certificate in the D2 category, it is also usable as a sanitizer on food-contact surfaces.
Which size fits which job, and the activated shelf life
Match the packet to the task, not just the volume. The 32 oz spray bottle (0.042 oz packet) is for spot cleaning and tool sanitization. The 1 gallon (0.17 oz packet) handles a single bench or a small-room touch-up. The 5 gallon (0.84 oz packet) is the workhorse for a full-room between-cycle turnover, which is why the 0.84 oz case of 12 is the common reorder for asmall operator cannabisroom. The 20 gallon drum (3.36 oz packet) is multi-room and MSO scale; amulti-state cannabis operatorstandardizing dilution across facilities orders at this size.
Activated solution has a clock on it. If any activated formula remains unused, store it in a dark, closed or sealed container in a cool, dark location away from sunlight and separate from food, and use it within 15 days of activation; record the activation date on the container and dispose after 15 days. Non-activated foil packets, by contrast, carry a 2-year warranty and keep longer if the foil is intact and stored in a temperature-controlled space. Procurement and QA leads get the SDS, EPA label, and account pricing in one place through acannabis procurementaccount, and reorder the 0.84 oz case on shop.groclarity.com.
Where to find the label, and what governs
This page is a working reference, not a replacement for the product label. The full directions for use, the complete kill list, the precautionary statements, and the current EPA registration detail live on the ProKure V label hosted at prokuresolutions.com. When a number on this page and the number on the current label ever differ, the label wins, every time. That is not a disclaimer for its own sake: it is a violation of federal law to use an EPA-registered product in a manner inconsistent with its labeling, so the label is the authority and this guide points you to it. Built on science. Backed by results.