Arkansas screens usable marijuana, cannabinoid concentrates, extracts, products, and edibles for Total Coliform. When coliform is detected, the sample is then tested for E. coli, and the batch fails at E. coli greater than 100 CFU/g. What Arkansas does not do is set a numeric Total Yeast and Mold ceiling the way enumeration states do, and it does not test for Aspergillus by species. So the mold-family question in Arkansas runs through the coliform-to-E. coli pathway, not through a cfu/g yeast-and-mold count or an Aspergillus speciation panel.

Where this rule lives in Arkansas law

Oversight sits with the Arkansas Medical Marijuana Commission and the Arkansas ABC, which administer the testing standards. The adopted testing framework dates to 2017, and the first Arkansas product cleared for sale in May 2019, so the rule has been live and enforced for years, not newly proposed. The standard applies across product categories: usable marijuana, cannabinoid concentrates, extracts, products, and edibles. A cultivator cannot assume a concentrate skips the microbial screen; the matrix changes the sampling, not the pass or fail logic.

Why Arkansas uses coliform and E. coli instead of a TYM number

Arkansas uses an indicator-organism approach. Rather than enumerate total fungal load against a ceiling, it treats coliform detection as the flag and E. coli as the confirmation, on the logic that those organisms indicate the contamination conditions that matter for safety. That is a different philosophy from an enumeration state like Massachusetts, which sets an allowable TYM limit on flower, or a species state like California, which fails a batch on any detectable pathogenic Aspergillus. Reporting from the Portland Press Herald captured the outlier framing bluntly, noting that "Arkansas and Washington don't test for either" in the context of the two common mold-testing methods. The practical read: Arkansas is lighter on the mold-count side, which puts more of the safety burden on your own prevention program.

What no numeric TYM ceiling does not mean

No TYM number is not a free pass. Visible mold at intake still fails a batch on inspection. Water activity and moisture problems still hit a lot. Civil liability and product-recall exposure still apply to a contaminated product that reaches a patient. And if you operate beyond Arkansas, the strictest state in your footprint controls your SOP, not the most lenient. An operator who builds to the Arkansas standard alone will fail the first time a lot moves into a species or enumeration state.

What Arkansas licensees must document

The certificate of analysis carries the coliform screen result, the E. coli confirmation result when the screen triggers it, and the batch and lot identifiers that tie the result to the product. A failed batch follows the state disposition path, including destruction where required. Keep the COA, the sampling record, and your sanitation log together, because that packet is what ties a clean result to a documented process.

The between-cycle sanitation protocol that keeps you off the trigger

The coliform and E. coli result is set by room hygiene long before the sample reaches the lab. The sanitation question for a flowering room is which chemistry you can use without a residue the next crop sits in or a crew evacuation that stretches turnover.

Between cycles, disinfect every hard, non-porous surface with ProKure V, a liquid chlorine dioxide disinfectant, EPA Reg. No. 87508-3-89334, used at 100 ppm for a 10-minute contact time. Its label states it is suitable for use with plants in the room because it treats surfaces, not the crop, and it leaves no residue and needs no rinse on treated surfaces. That residue-free, plant-adjacent profile is what bleach and quaternary ammonium products cannot match: bleach fumes mean evacuating the crew, and quats leave a film.

For an empty-room reset between harvests, ProKure G, a fast-release chlorine dioxide gas, EPA Reg. No. 87508-2-89334, works in 4 to 6 hours and then needs a 1-hour ventilation before re-entry. ProKure G carries the label disclaimer that it is not for use with plants, crops, or feed, so the room must be empty of plants and people. For ongoing air quality with plants present, ProKure D, a slow-release chlorine dioxide gas, provides ClO2 protection for up to 30 days; it is not an EPA-registered product and not labeled for sale as a pesticide under 40 CFR, and it carries no kill claims. Match each product to its label and read the label before you apply anything in a room with plants.

How Arkansas compares to the states a multi-state operator also runs in

If your footprint crosses state lines, standardize to the strictest rule. Missouri sets no numeric TYM ceiling either, but it enforces Aspergillus species non-detect and Salmonella and STEC non-detect. Oklahoma uses a numeric Total Yeast and Mold ceiling on standard product. California fails a batch on any detectable pathogenic Aspergillus species. Arkansas, with its coliform-to-E. coli pathway, is the most permissive of the group on the mold-count side. Build your IPM SOP to the species non-detect standard and Arkansas becomes a reporting detail rather than a design driver.